Dear Sirs,
Commercial Information Circular No. 611/2013
Chile : Low-voltage Electrical Conductors Certification Requirements Compliance Deadlines Extended
The Chilean government issued Exempt Resolution No. 1330/2013 on 29 May 2013 to extend the compliance deadlines of low-voltage electrical conductors certification requirements.
2.The Chilean government issued Exempt Resolution No. 960/2011 on 1 April 2011 to require importers, domestic manufacturers and sellers of low-voltage electrical conductors to obtain safety conformity certification. The effective date of the Exempt Resolution was 1 June 2013.
3.Exempt Resolution No. 1330/2013 of 29 May 2013 extended the abovementioned deadline for certification requirements as follows:
Protocol PE No. |
Test | Compliance Date | ||
---|---|---|---|---|
PE 2/14 PE 2/15 |
Mechanical properties of insulation: Tensile strength and elongation, with and without aging | 31 December 2013 | ||
Hot set test for insulation | ||||
Water absorption in insulation (gravimetric method) | ||||
Insulation contraction test | ||||
Mechanical properties of the cover: Tensile strength and elongation, with and without aging | ||||
Mass loss of the cover in hot air oven | ||||
Pressure test of the cover at high temperatures (penetration) | ||||
Performance of the cover at low temperatures (bending, stretching and cold impact) | ||||
Thermal shock test of the cover | ||||
Fire-resistance test. No flame propagation | 30 June 2014 | |||
PE 2/16 PE 2/17 |
Voltage test for 4 hours | 31 December 2013 | ||
Hot set test for insulation | ||||
Water absorption in insulation (gravimetric method) | ||||
Insulation contraction test | ||||
Mechanical properties of the cover: Tensile strength and elongation, with and without aging | ||||
Pressure test of the cover at high temperatures (penetration) | ||||
Performance of the cover at low temperatures | ||||
Additional aging trials on finished cable parts | ||||
Water absorption for the cover (gravimetric method) | ||||
Fire-resistance test. No fire propagation - vertical flame (Category C) | 30 June 2014 | |||
Fume emission test | 31 December 2013 | |||
Acid gas emission (bromine and chlorine) | 30 June 2014 | |||
PH and conductivity test | 31 December 2013 | |||
Fluorine content test | 30 June 2014 | |||
PE 2/18 PE 2/19 PE 2/20 |
Insulation impact test at -15°C | 31 December 2013 | ||
Unipolar cable flame test | 30 June 2014 | |||
Fire propagation test (Category C) | ||||
Fume emission test | 31 December 2013 | |||
PH and conductivity test | ||||
Chlorine and bromine content test | 30 June 2014 | |||
Fluorine content test |
4.For details, traders are advised to consult their importers in Chile and/or the abovementioned Chilean Exempt Resolution (in Spanish), which is available at http://www.leychile.cl/Navegar?idNorma=1051777&buscar=resolucion+1330.
ENQUIRIES
5.For enquiries about the content of this circular, please contact Miss S Y TANG at telephone number 2398 5405.
Yours faithfully,
(Ms Cindy Cheng)
for Director-General of Trade and Industry
Note: | While every effort is made to ensure the accuracy of the above information, the Department cannot guarantee this to be so and will not be held liable for any reliance placed on the same. |